Profile
Products
Enquiry
Contact
 Underground Sewerage Pipes 
All Products | Pipes | UPVC Pressure Fittings | UPVC Soil, Waste and Ventilating Fittings

Product Code : N/A
Product Category : Pipes Click to View Larger Image
Product Name : Underground Sewerage Pipes
Product Description :

Brand : Kentra
Colour : Golden Brown (for Sewerage Pipes)
Length : Pipes are supplied in lengths of 6m and plain ended

Nom Size
(mm)

Outside Diameter (mm)

Underground Sewerage Pipes�

BS 4660 : 1989
MS 1063 : 2002
Thickness (mm)

110

110.00 � 110.40

3.2 (min)

160

160.00 � 160.60

4.1 (min)

Features
When pipes are buried underground, numerous loads such as backfill soil, liquid weight in the pipe, pavements and moving vehicles act on the pipe.

As a result of the complexities involved, external pressure significantly varies depending on the nature of soil, method of back filling, the state after back fill etc.�

Soil and Wheel Pressure
With reference to the table below, it is seen that external pressure on the pipe becomes almost almost constant on pipes buried at depths greater than 1.2 meters. In other words, if pipes are buried at a depth of 0.8 to 1.0 meter, they are usually quite safe to earth and wheel pressure.

Depth� of Installation
H (cm)

10

30

60

90

120

150

180

Soil pressure
P1 (kg/m2)

190

530

990

1.380

1.710

2.000

2.240

Wheel pressure
P2 (kg/m2)

36.100

11.600

4.310

2.250

1.370

920

660

P1 + P2

36.290

12.130

5.300

3.630

3.080

2.920

2.900

 

 

 
Welcome
Profile
Products
Enquiry
Contact
Copyright hold by Chianta Plastic Industries Sdn Bhd
This Program(WTEfw.Creator) is developed by WTExpo.com

Underground Sewerage Pipes uPVC Pipes Brand : Kentra Colour : Golden Brown (for Sewerage Pipes) Length : Pipes are supplied in lengths of 6m and plain ended Nom Size (mm) Outside Diameter (mm) Underground Sewerage Pipes� BS 4660 : 1989 MS 1063 : 2002 Thickness (mm) 110 110.00 � 110.40 3.2 (min) 160 160.00 � 160.60 4.1 (min) Features When pipes are buried underground, numerous loads such as backfill soil, liquid weight in the pipe, pavements and moving vehicles act on the pipe. As a result of the complexities involved, external pressure significantly varies depending on the nature of soil, method of back filling, the state after back fill etc.� Soil and Wheel Pressure With reference to the table below, it is seen that external pressure on the pipe becomes almost almost constant on pipes buried at depths greater than 1.2 meters. In other words, if pipes are buried at a depth of 0.8 to 1.0 meter, they are usually quite safe to earth and wheel pressure. Depth� of Installation H (cm) 10 30 60 90 120 150 180 Soil pressure P1 (kg/m2) 190 530 990 1.380 1.710 2.000 2.240 Wheel pressure P2 (kg/m2) 36.100 11.600 4.310 2.250 1.370 920 660 P1 + P2 36.290 12.130 5.300 3.630 3.080 2.920 2.900